ANALISIS PERBANDINGAN PERILAKU SEISMIK PADA STRUKTUR GEDUNG 6 LANTAI DENGAN VARIASI SISTEM LATERAL

Authors

  • Dwi Devina Linggi Universitas Mahasaraswati Denpasar
  • I Ketut Diartama Kubon Tubuh
  • I Gede Gegiranang Wiryadi Mahasaraswati Denpasar University
  • I Putu Agus Putra Wirawan Universitas Mahasaraswati Denpasar
  • I Made Sastra Wibawa Universitas Mahasaraswati Denpasar

DOI:

https://doi.org/10.36733/jitumas.v6i2.15051

Keywords:

perilaku seismik, sistem penahan gaya lateral, bracing, dinding geser, SRPM

Abstract

Indonesia merupakan wilayah rawan gempa sehingga gedung bertingkat, terutama gedung berkategori risiko tinggi seperti rumah sakit, perlu dilengkapi sistem penahan gaya lateral yang memadai. Penelitian ini bertujuan membandingkan perilaku seismik gedung rumah sakit 6 lantai di Banyuwangi dengan lima variasi sistem lateral, yaitu rangka terbuka (open frame, OF), bracing X (BFX), bracing V (BFV), bracing inverted-V (BFIV), dan dinding geser (shear wall, SW). Analisis menggunakan metode spektrum respons ragam pada program analisis struktur dengan acuan SNI 1726:2019. Parameter yang dibandingkan adalah periode struktur, gaya geser dasar, simpangan, dan simpangan antar tingkat. Seluruh model memenuhi syarat gaya geser dinamis tidak kurang dari 100% gaya geser statik, dan keempat model sistem ganda memenuhi syarat kontribusi rangka pemikul momen minimum 25%. Simpangan maksimum arah X pada model OF, BFX, BFV, BFIV, dan SW berturut-turut sebesar 55,646; 50,391; 58,600; 54,357; dan 22,697 mm, sedangkan arah Y sebesar 56,873; 50,576; 60,269; 56,817; dan 22,552 mm; seluruhnya di bawah batas izin. Model SW menghasilkan simpangan maksimum terkecil, sedangkan simpangan antar tingkat maksimum terkecil terjadi pada model BFX, yaitu 8,289 mm (arah X) dan 8,374 mm (arah Y). Penambahan pengaku lateral meningkatkan gaya geser dasar hingga sekitar 1,8–1,9 kali model OF, dan dinding geser paling efektif mereduksi simpangan struktur.

References

Amadio, C., Bomben, L., & Noè, S. (2022). Design of X-Concentric Braced Steel Frame Systems Using an Equivalent Stiffness in a Modal Elastic Analysis. Buildings, 12(3), 359. https://doi.org/10.3390/buildings12030359

Anwar, S. N. R., Ernanda, F., Sulton, M., Anwar, S. A., & Anwar, M. S. (2024). A comparative study of dynamic performance the shear-wall and bracing shapes on the tall building in seismic area. Edelweiss Applied Science and Technology, 8(4), 460–478. https://doi.org/10.55214/25768484.v8i4.1394

Badan Standardisasi Nasional. (2020). SNI 1729 2020 Spesifikasi untuk Bangunan Gedung Baja.

Bohara, B. K., & Saha, P. (2022). Nonlinear behaviour of reinforced concrete moment resisting frame with steel brace. Research on Engineering Structures and Materials. https://doi.org/10.17515/resm2022.383st0404

Filipus, C., Simanjuntak, P., & Tampubolon, S. P. (2024). Comparison of special moment resisting frame system and dual system on earthquake resistant reinforced concrete building structure based on SNI 1726:2019. AIP Conference Proceedings, 040012. https://doi.org/10.1063/5.0209594

Hendrawan, R., & Christianto, D. (2022). Faktor Daktilitas Struktur Beton Bertulang dengan Bresing Baja Eksentris. JMTS: Jurnal Mitra Teknik Sipil, 881–888. https://doi.org/10.24912/jmts.v5i4.20425

Husna, I. A., Musbar, M., & Miswar, K. (2026). Analisis Perbandingan Perilaku Struktur Gedung Bertingkat Menggunakan SRPMK dengan Dual System. Portal: Jurnal Teknik Sipil, 17(2), 293. https://doi.org/10.30811/portal.v17i2.8803

Kang, Y., Mei, J., Wu, X., & Wang, L. (2025). Lateral Resistance of Modular CFS Shear Wall Connected with Rectangular Steel Tubes and Its Contribution to Frame Structures. Materials, 18(23), 5257. https://doi.org/10.3390/ma18235257

Laissy, M. Y. (2022). Effect of Different Types of Bracing System and Shear Wall on the Seismic Response of RC Buildings Resting on Sloped Terrain. Civil Engineering Journal, 8(9), 1958–1976. https://doi.org/10.28991/CEJ-2022-08-09-014

Lee, B.-G., Kim, J.-Y., Jung, J.-S., & Lee, K.-S. (2023). Seismic Capacity of R/C Buildings Retrofitted with a V-Bracing System Equipped with a Novel Laterally Layered Friction Damper. Applied Sciences, 13(24), 13205. https://doi.org/10.3390/app132413205

O. Tang, T., & K.L. Su, R. (2014). Shear and Flexural Stiffnesses of Reinforced Concrete Shear Walls Subjected to Cyclic Loading. The Open Construction and Building Technology Journal, 8(1), 104–121. https://doi.org/10.2174/1874836801408010104

Rahman, M. A., Teguh, M., & Saleh, F. (2021). Comparative study of structural response on multi-story buildings with shear wall and bracing systems. IOP Conference Series: Earth and Environmental Science, 933(1), 012009. https://doi.org/10.1088/1755-1315/933/1/012009

SNI 1726:2019 Tata Cara Perencanaan Ketahanan Gempa Untuk Struktur Bangunan Gedung Dan Nongedung, 238 (2019).

SNI 1727:2020 Desain Beban Minimun Untuk Bangunan Dan Struktur Lainnya, 1 (2020).

SNI 2847:2019 Persyaratan Beton Struktural Untuk Bangunan Gedung Dan Penjelasan, 695 (2019).

Sukrawa, M., Susila, I. G. A., & Putra, A. P. (2019). Strengthening Using Type-V Bracing for Structural Integrity of Reinforced Concrete Frame Resists Earthquake Loads. Journal of International Conference Proceedings. https://doi.org/10.32535/jicp.v2i1.434

Wiryadi, I. G. G., & Sudarsana, I. K. (2019). Analisis Pengaruh Bentuk Dinding Geser Beton Bertulang Terhadap Kapasitas dan Luas Tulangan. Jurnal Spektran, 7(2), 187–194.

Wiryadi, I. G. G., Tubuh, I. K. D. K., Wirawan, I. P. A. P., & Putra, G. J. (2026). Analisis Efektivitas Sistem Bracing-X Dan Inverted-V pada Struktur Baja Empat Lantai di Wilayah Gempa Tinggi. Jurnal Ilmiah Kurva Teknik, 15(1), 1–12. https://doi.org/10.36733/jikt.v15i1.12532

Xu, W., Zhao, Y., Yang, W., Zhang, J., & Chen, D. (2023). Seismic performance of RC frame-shear wall dual structural systems. Structures, 58, 105610. https://doi.org/10.1016/j.istruc.2023.105610

Yusuf, K., Fasdarsyah, F., Usrina, N., Fauzan, M., & Nurahim, R. (2023). Comparative Study of Strengthened Steel Structure Behavior Using Bracing and Shearwall. International Journal of Engineering, Science and Information Technology, 3(2), 77–87. https://doi.org/10.52088/ijesty.v3i2.456

Published

2026-10-30

How to Cite

Linggi, D. D., Tubuh, I. K. D. K., Wiryadi, I. G. G., Wirawan, I. P. A. P., & Wibawa, I. M. S. (2026). ANALISIS PERBANDINGAN PERILAKU SEISMIK PADA STRUKTUR GEDUNG 6 LANTAI DENGAN VARIASI SISTEM LATERAL. Jurnal Ilmiah Teknik Universitas Mahasaraswati Denpasar (JITUMAS), 6(2), 143–150. https://doi.org/10.36733/jitumas.v6i2.15051